Bell Furnace with two Bases for Heat Treatment
Maximum size of the load:
Length = 10000 mm
Width = 3000 mm.
Height = 3000 mm.
Temperature:
Working = from 600°C to 1150°C
Max = 1200°C
Weight of the load = 50 tons.
Controlled cooling
It is made by air ventilation that releases the ambient temperature air taken from inside the
warehouse by 2 pipelines, conducted at the same level of burners and accompanied by 20
motorized valves operated by the PLC
Cooling temperature from 1000 ° C to 550 ° C in 1.5 h